Temperature calibration is essential for ensuring accurate measurements in industrial and laboratory settings. The PR611 Series Multifunctional Dry Block Calibrator is a cutting-edge device that combines dual-zone temperature control, automatic calibration, and high-precision measurement capabilities. This guide provides a comprehensive overview of the PR611 Series, including its features, setup, and best practices for use.
The PR611 Series is designed to meet the demanding requirements of temperature calibration professionals. Whether used in industrial manufacturing, research laboratories, or metrology applications, this device offers unparalleled performance and reliability.
Dual-Zone Temperature Control: Ensures uniform temperature distribution for high-accuracy calibration.
Rapid Heating and Cooling: Intelligent control algorithms optimize temperature adjustments.
Full-Function Electrical Measurement Channel: Supports thermocouples, RTDs, transmitters, and temperature switches.
Reference Measurement Channel: Provides multi-point interpolation correction for better traceability.
Editable Task Mode: Enables complex calibration tasks with multiple setpoints.
Automatic Temperature Switch Calibration: Simplifies the process of testing switch activation points.
HART Transmitter Calibration: Built-in 250Ω resistance and 24V loop power for transmitter calibration.
USB Storage Support: Allows data logging and export in CSV format for easy analysis.
The PR611 Series includes different models, such as:
PR611A/H – Suitable for low to medium temperature calibration (-30°C to 155°C).
PR613A/H – Designed for high-temperature applications (RT+10°C to 700°C).
Before using the calibrator, inspect it for any visible damage. Ensure all accessories, including the thermostatic block extraction clip, power cable, and user manual, are present.
Connect the device to a 220VAC ±10%, 50Hz power source.
Turn on the power switch located on the side of the unit.
Allow the device to complete its self-check process before proceeding.
If the device does not turn on:
Ensure the fuse is intact.
To replace, remove the fuse cover, replace the fuse with a matching type, and secure the cover.
The user interface consists of two primary sections:
Temperature Control Interface – For setting and maintaining calibration temperatures.
Calibration Interface – For performing thermocouple, RTD, transmitter, and switch calibrations.
Current Temperature Display – Shows real-time internal or reference sensor temperature.
Set Value (SV) Input – Allows users to input a target calibration temperature.
Temperature Stability Indicator – Ensures the temperature remains within the set stability range.
USB Status Indicator – Displays the connection status of external USB storage.
Navigate to the temperature control settings.
Select the temperature control sensor (internal or external reference).
Set the target calibration temperature (SV value).
Adjust the stability conditions (e.g., ±0.01°C over 5 minutes).
Start the temperature control process.
Connect the thermocouple to the Mini TC socket or terminal block.
Set the calibration temperature points.
Choose the cold junction compensation method (internal sensor or ice bath).
Start the calibration and monitor temperature stability.
Record the results and save them to a USB drive if needed.
Connect the RTD using two, three, or four-wire configurations.
Select the appropriate RTD type (Pt100, Pt500, Cu100, etc.).
Set the calibration temperature points.
Run the calibration cycle and log the results.
Connect the transmitter to the 50mA or 50V measurement terminals.
Enable HART communication mode (if applicable).
Set zero and span values for the transmitter.
Initiate the calibration process and compare results with reference data.
Connect the switch terminals to the calibrator.
Define the operating temperature and deviation range.
Start the calibration and wait for the switch to activate.
Verify switch response and save the data.
The PR611 supports CSV file export, making it easy to:
Store calibration data for regulatory compliance.
Transfer data to a PC for further analysis.
Maintain historical records for quality assurance.
Issue | Possible Cause | Solution |
---|---|---|
Device won’t turn on | Blown fuse or power issue | Replace fuse, check power connection |
Temperature not stabilizing | External interference or block misalignment | Reposition device, ensure block is secure |
USB not detected | Drive format not supported | Use FAT32 formatted drive |
Sensor reading inaccurate | Loose connection | Reconnect and secure sensor wires |
Clean the isothermal block regularly to prevent contamination.
Store the device in a dry, non-condensing environment.
Avoid excessive force or impact on the display screen.
Unmatched accuracy with 0.01°C stability.
Versatile functionality, supporting multiple sensor types.
Portable design, ideal for both industrial field use and laboratory settings.
User-friendly interface with touch-screen controls.
The PR611 Series Multifunctional Dry Block Calibrator is a powerful and reliable solution for temperature calibration needs. Its dual-zone control, high accuracy, and automated calibration capabilities make it an essential tool for professionals in the industrial, laboratory, and metrology sectors. By following the steps outlined in this guide, users can maximize the performance and longevity of their calibrator while ensuring precise and consistent calibration results.